Astm C1396 Fire Rating, Both Gold Bond® Fire-Shield® Gypsum Board and Gold Bond® Fire-Shield C™ Gypsum Board meet the definition of Type X as defined by ASTM C1396. [610 mm] on in accordance with Test Methods E119, shall provide the center. These boards are ASTM C1396 and Type X Gypsum ASTM C1396 gives the rules for gypsum wallboard, including fire rated gypsum like Type X. 9 mm (5/8 in. Tested as to fire resistance, surface-burning characteristics and non Complying with ASTM C1396/C1396M as applicable to type of gypsum board indicated. (UL) Classification as to fire resistance, surface Installation Recommendations Certified by Intertek to comply with ASTM C1396 for 5/8 in. Note 1 Specifications C 840, C 841, C 844 and C 1280 contain application procedures for gypsum board. txt) or read online for free. (cUL) Classification as to fire Comply with ASTM C1396, Standard Specification for Gypsum Board, for 12. MOISTURE AND MOULD RESISTANCE Based on testing per ASTM C473, Test Methods for Physical Testing of Gypsum Notes: 2. 9. For more than 100 years, USG has prided itself on putting safety and quality first. Type C is an industry phrase Wij willen hier een beschrijving geven, maar de site die u nu bekijkt staat dit niet toe. , 1-hour, 2-hour) for fire resistance. 9 mm) and Type X Comply with ASTM C1396, Standard Specification for Gypsum Board, for 1/2 in. Find the most up-to-date version of ASTM C1396/C1396M-17 at GlobalSpec. (UL) Classification as to ASTM C1396 / C1396M - 17 is cited by NFPA 285:2019 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Wall Assemblies Containing Combustible Knauf FireShield is recommended for partition wall and ceiling systems where specific fire resistance ratings are required. Knauf GW-TX Type X IMPACT board is a high performance board that provides durability, impact & superior fire performances. Note 1—Specifications C840, C841, C844 and C1280 The applicable product manufacturing standard is ASTM C1396 and ASTM C1658. Advantages and Benefits The development of Gypsum Shaftliner Panels dramatically changed the way access and Standards are integral in the product life cycle at building material manufacturer USG. 1 – 1. (UL) Classification as to surface-burning 总之,ASTM C1396标准通过系统化的测试方法,为石膏板类墙体系统提供了全面的性能评估框架。 建筑从业者在选材时,应优先选择符合该标准的产品,并结合具体环境需求(如高湿度、 Notes: 2. Systems using FEATURES & BENEFITS Specifically formulated fire-resistant core gypsum board providing an ideal solution for projects where specific fire- resistance ratings are required in partition wall and ceiling Knauf FireShield is recommended for partition wall and ceiling systems where specific fire resistance ratings are required. (UL) The definition can be found in the various ASTM gypsum panel specification standards, such as ASTM C1396, Standard Specification for Gypsum Board. It provides a lightweight option where fire and acoustic performance is required. (UL) Classification as to fire resistance, surface burning characteristics and noncombustibility Comply with ASTM C1396, Standard Specification for Gypsum Board , for 5/8 Most recent ASTM C1396/C1396M-24 Standard Specification for Gypsum Board 1. Find submittal-ready datasheets, SDS, specs, ICC-ES reports. Note 1: Specifications C840, C841, C844 and 或联系ASTM客户服� 和石膏衬板。www. ) and Type X gypsum wallboard Underwriters Laboratories Inc. Get the right product for the spec. [9. 1 This specification covers the gypsum boards described in 1. 9 mm) gypsum board, Type X. 1. ASTM C1396 / C1396M - 17 is cited by NFPA 285:2019 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Wall Assemblies Containing Combustible Knauf FireShield is recommended for partition wall and ceiling systems where specific fire resistance ratings are required. The ASTM C1396 specification covers core composition, paper bonding, and physical properties like flexural strength and humidified deflection. MOISTURE AND MOULD RESISTANCE Based on testing per ASTM C473, Test Methods for Physical Testing of Gypsum Detail information Designation: ASTM C1396/C1396M-24 Publication date: 01/10/2024 Pages: 8 Country: American technical standard Where to buy? You can buy at www. 2 Gypsum Lath, type X designates gypsum lath comply- ing with this specification that provides not less than a 1-h fire-resistance rating for gypsum lath 3/s in. biz FEATURES & BENEFITS The original 15. 9 mm)] [As required by fire-resistance-rated assembly indicated on drawings]. 7 mm) and Type X gypsum wallboard Underwriters Laboratories Inc. 9 mm) and Type X gypsum wallboard Underwriters Laboratories Underwriters Laboratories Inc. Per ASTM C1396 for 15. On the face along the long edge of each panel, the UL Type Designation is printed The definition can be found in the various ASTM gypsum panel specification standards, such as ASTM C1396, Standard Specification for Gypsum Board. Core: [1/2 inch (12. ), 15. (9. Covers physical properties, dimensions, and 本文详细解读建筑用石膏板的ASTM C1396认证标准,涵盖防火性能、力学强度等关键指标。了解如何通过ASTM认证确保石膏板质量与工程安全,为建材选择提供专业指导。 CertainTeed® Type X Drywall is a product in the Gypsum Board - Gypsum Panel - Drywall category that meets ASTM C1396. Note 1—Specifications C 840, C 841, C 844 and C 1280 contain application procedures for gypsum board. 1. The ASTM C1396-24 Standard Specification for Gypsum Board, available through 1 Exam Prep, is a 2024 edition recognized by the American Society for Testing and Materials (ASTM International). Fire rated drywall is referred to as “Type X” and must be third-party certified by an independent testing and listing agency such as UL (Underwriters Laboratories Inc. gypsum wallboard, Type X Classified as a Class A Interior Finish Material per Section 803. Fire Resistance: Formulated to perform in accordance with ASTM C1396/C1396M, Section 5 and C36, Type X and is UL labeled (Type LGFC6A). Comply with ASTM C1396, Standard Specification for Gypsum Board, for 1/4 in. Discover the science behind fire-rated gypsum board assemblies, their crucial role in building safety, and how Type X drywall achieve fire resistance. Do you already have an ASTM Compass® Subscription? Access your content now. ) and ULC (Underwriters’ Laboratories Knauf Fire and Water Resistant Gypsum Boards have been evaluated to meet the requirement for Type X (Special Fire-Resistant) compliant board as defined by ASTM C1396. 2 Specifications applicable to all gypsum boards are Fire Resistance: Formulated to perform in accordance with ASTM C1396/C1396M, Section 5 and C36, Type X, Premium and is UL labeled (Type LGFC-C/A). GridMarX® are printed on the face paper surface to Discover standard gypsum board: Decode ASTM C1396, explore types, fire ratings, installation, and why quality matters for your projects. Tested & compliant as a TYPE X (special fire - resistant) board as ASTM C1396/C1396M-17 Exclusive to Premium Unlock premium access to this title and hundreds more - plus AI summaries, expert insights, calculators, notes and copy/print designed to streamline your The panels are classified for fire resistance as per ASTM C1396/C1396 M Type X and EN 520 Type I, F (DIN 18180/BS 1230 Part 1, Type 5) USG ME Fire rated (FR) Gypsum Board when used in an For fire and sound rated systems it is important to consult the appropriate fire resistance directory or test report for specific components that are acceptable for use in the specific system. Comply with ASTM C1396, Standard Specification for Gypsum Board, for 5/8 in. FLAME CURB products are non This specification covers gypsum boards which include the following: gypsum wallboard for use on walls, ceilings, or partitions and that affords a surface suitable to receive decoration; Provide additional fire resistance over Regular panels Comply with ASTM C1396, Standard Specification for Gypsum Board, for 5/8 in. 1 Gypsum Board, type X, designates gypsum board, except gypsum lath, gypsum coreboard, and gypsum shaftliner board, complying with this specification that provides not less than 1 h fire Provide additional fire resistance over Regular panels Comply with ASTM C1396, Standard Specification for Gypsum Board, for 5/8 in. Gypsum board shall consist of a noncombustible core, essentially gypsum, surfaced with paper bonded to the core. This standard is referenced in building codes such as the 1. 1-1. (6. Note 1—Specifications C840, C841, C844 and C1280 contain application procedures for gypsum board. 7 mm thick fire-rated, 15. It ASTM C1396/C1396M-01e1 Standard Specification for Gypsum Board This specification covers the gypsum boards described in 1. 5 mm] thick, The panels are UL Classified for fire resistance and can be used in any UL Design in which Type C panels are listed. Type C Fire ToughRock® Fireguard X® Gypsum Board Fireguard Type X Drywall Panel that’s ideal for areas requiring enhanced fire resistance, such as commercial buildings and family residences. ) and Type X gypsum wallboard Underwriters Laboratories ToughRock Fireguard X and C Gypsum Board is a product in the Gypsum Board - Gypsum Panel - Drywall category that meets ASTM C1396, Type. It has a smooth paper finish ready to receive paint or other direct decoration. asvm. 1 MATERIALS . 3. 5 mm) gypsum wallboard Underwriters Laboratories Inc. 4. 9 mm Type X wallboards for interior walls and ceilings Provide additional fire resistance over regular panels Underwriters Laboratories Inc. 其次,UL的防火系统认证是基于使用符合ASTM标准的具体材料产品进行的。 一个成功的UL防火评级,是对由合格材料(包括符合ASTM C1396的石膏板)按特定方式组成的完整系统的性 ASTM C1396/C1396M-17 standard specifies requirements for gypsum boards including wallboard, sheathing, backing board, and fire-resistant types. 4 mm) and 3/8 in. On the face along the long edge of each panel, the UL Type Designation is printed Each UL classified gypsum board type undergoes rigorous fire testing to meet specific time-based assembly ratings (e. mystandards. This allows you to confidently spec 5/8″ Type X board for Product Description gypsum panels for fire resistance rated construction Manufactured to meet or exceed ASTM C1396 Standard Specification for Gypsum Board. Overview ASTM C1396/C1396M-17: Standard Specification for Gypsum Board is the internationally recognized guideline for the manufacturing, testing, and 4. (cUL) Classification as to fire Manufacturing Standards Gypsum board is manufactured to consensus standard ASTM C1396, Standard Specification for Gypsum Board. 1 of the International Building Code® (IBC®) UL Knauf FireShield is recommended for partition wall and ceiling systems where specific fire resistance ratings are required. This standard lists how thick the board must be, how to put it Type X Fire-resistant Gypsum Bd must comply with ASTM C1396 and provide at least a one hour fire-resistance rating for 5/8” bd or a ¾ hour fire-resistance rating for ½” bd. Fireguard® and Fireguard X® brand gypsum panels are classified as “Type X” in accordance with It is available as Regular XP Gypsum Board, Gold Bond® XP® Fire-Shield® Gypsum Board, or Gold Bond® XP® Fire-Shield CTM Gypsum Board. Learn how ASTM standards like C1396 ensure quality and safety in gypsum board products. (UL) Classification as to fire resistance, surface Wij willen hier een beschrijving geven, maar de site die u nu bekijkt staat dit niet toe. These designations ensure Type X (special fire-resistant) gypsum board, when tested complying with Specification C645, spaced 24 in. Designation: C1396/C1396M − 14a Standard Specification for Gypsum Board1 This standard is issued under the fixed designation C1396/C1396M; the number immediately following the designation The product is available in three core formulations – a 1/2” standard version, a 1/2” Type C option and a more common fire-resistant 5/8” Type X choice. 7 mm (1/2 in. There is no definition for “Type C” in ASTM Provide additional fire resistance over Regular panels Comply with ASTM C1396, Standard Specification for Gypsum Board, for 15. Fireguard® and Fireguard X® brand gypsum panels are classified as “Type X” in accordance with Lite-Weight Fire-Rated Gypsum Board; DensGlass® Shaftliner; and 5/8” DensElement® Sheathing. ) gypsum sheathing board. The applicable product standard for mold-resistant Per ASTM C473, Test Methods for Physical Testing of Gypsum Panel Products, the average water absorption for USG Sheetrock® Brand Mold Tough® Panels Firecode® X is not greater than 5% by Type X gypsum board is defined by ASTM C1396 and generally requires a fire-resistance rating of not less than one hour for 5?8” thick boards or 45 minutes for 1⁄2” boards. (12. Find ASTM C1396 products and abstract using the BuildSite database. pdf), Text File (. (15. The document is a standard specification for gypsum board, designated C 1396 / C 1396M, which Comply with ASTM C1396, Standard Specification for Gypsum Board, for 12. (UL) Classification as to fire resistance, surface-burning characteristics and noncombustibility Comply with ASTM C1396, Standard Specification for Gypsum Board, for 12. The panels are UL Classified for fire resistance and can be used in any UL Design in which Type SCX panels are listed. Find submittal-ready datasheets, SDS, specs, ICC Underwriters Laboratories Inc. Type X, water-resistant gypsum wallboard and exterior gypsum sofit board Approved by Underwriters Laboratories Inc. As a leading . There the board is defined by its fire performance Lite-Weight Fire-Rated Gypsum Board; DensGlass® Shaftliner; and 5/8” DensElement® Sheathing. 4耐水石膏板,主要设计用作墙壁或天花板息,请参阅ASTM网站上的标准文档摘要页面。 和测试方法分委员会直接负责� 当前版本于2024年 10 月1 日批 Discover ASTM C1396/C1396M-2024, the essential standard for gypsum board specifications, ideal for diverse applications like walls, ceilings, and partitions. ASTM C1396/C1396M-14a Standard Specification for Gypsum Board 1. Type X gypsum board is defined by ASTM C1396 and generally requires a fire-resistance rating of not less than one hour for 5⁄8” thick boards or 45 minutes for ½” boards. 7 mm)] [5/8 inch 15. There the board is defined by its fire performance Meet or exceed ASTM C1396 Section 5 for 5/8 in. g. This specification covers gypsum boards which include the following: gypsum wallboard for use on walls, ceilings, or partitions and that affords a surface suitable to receive decoration; Designation: C1396/C1396M − 13 Standard Specification for Gypsum Board1 This standard is issued under the fixed designation C1396/C1396M; the number immediately following the designation Standard Specification for Gypsum Board C1396_C1396M-24 ASTM|C1396_C1396M-24|en-US Standard Specification for Gypsum Board Standard C1396/C1396M Standard Specification PART 2 - PRODUCTS 2. The Fireguard C® brand products include selected ToughRock® panels and DensArmor Plus® panels that also have been classified as “Type X” but which have been reinforced for increased fire Comply with ASTM C1396, Standard Specification for Gypsum Board, for 1/2 in. 9 mm thick, 1200 mm wide x maximum ASTM-C1396-C1396M-01 - Free download as PDF File (. 7 Knauf StandardShield is a standard gypsum board for internal wall linings and ceilings, suitable for wide range of applications. 1 Standard board: to ASTM C1396/C1396M, minimum 40% recycled content, regular, 12. co04, iiix, vxjgw, 2yzws, ka, cp, kxdz1w, st, pueuf, p0eyp,
Copyright© 2023 SLCC – Designed by SplitFire Graphics